Radiatherm Contact Me

Products - Terma Radiator

Technical Properties

Model

Terma

Section Width (mm)

80

Radiator Lenght (mm)

n x 80 ( n = number of section )

Radiator Thikness (mm)

40

Distance occupied from the wall (mm)

95

Distance between wall and the axe (mm)

75

Connection (inch)

1/2

Entre-axes (mm)

Total Height - 45

  • Detail & Technical Features
  • Heat Data
  • Color and Wood Pattern Options
  • Connection Types

Specially designed using a cross flow technic allowing Terma higher heat output and homogenous heat distribution in the room . This technic comprises “double heat transfer systems “ which occurs between the sections as a preheat area and than air flows through the louvres where the air is further heated by conduction and than returns to the room as hot air with higher speed and higher temperatures . Natural convection rate in Radiaterm-Terma is about 73%-75% of the total hot air generated by the radiator . Terma like all the other Models of Radiatherm is suitable to all installation system. Also is suitable for bottom twin entry connection called HB connections with 50 mm betwen inlet and outlet axes . The Valve İntegrated version with thermostatic TRV head is also possible upon request .

 Model  Height (mm)  Entre-axes (mm)  Heat output per section(kcal/h)  Heat output per section (watt)  Water Content (liter)

RT 290

290

245

98

114

0,062

RT 390

390

345

122

142

0,080

RT 470

470

425

141

164

0,090

RT 490

490

445

145

169

0,097

RT 545

545

500

158

184

0,103

RT 590

590

545

169

197

0,115

RT 620

620

575

176

205

0,120

RT 770

770

725

211

245

0,147

RT 890

890

845

239

278

0,168

RT 920

920

875

246

286

0,173

RT 1020

1020

975

270

314

0,191

RT 1270

1270

1225

329

383

0,235

RT 1520

1520

1475

387

450

0,279

RT 1770

1770

1725

446

519

0,323

RT 2020

2020

1975

505

587

0,368

Color Options Wood Pattern Options
 White Ral 9010  RD - 1000
 Cream Ral 1013  RD - 1010
 Chrome Yellow Ral 1023  RD - 1020
 Orange Ral 2008  RD - 1030
 Green Ral 6019  RD - 1040

By-Pass Main Connection


Bottom opposite end connection


Up and opposite end connection


Twin connection bottom feed with integrated valve


Up and bottom same end connection


Twin connection bottom feed


The distance between the valve axes in bottom-opposite-end connection and up-opposite bottom end connection is to be taken as (45x2)=90mm in addition to radiator length. For up and down the same end connection valve center is 45 mm from the radiator. For HB connection 50 mm is between centers and 40 mm. From the start point of the radiator to the first inlet center.