Technical Properties

Model

AtlantİK

Section Width (mm)

80

Radiator Lenght (mm)

n x 80 ( n = number of section )

Radiator Thikness (mm)

105

Distance occupied from the wall (mm)

150 or 135

Distance between wall and the axe (mm)

98 or 83

Connection (inch)

1/2

Entre-axes (mm)

Total Height - 30

  • Detail & Technical Features
  • Heat Data
  • Color and Wood Pattern Options
  • Connection Types

Atlantik ‘s approach to design is minimalist .İt’s straight lines, sharp edges , and plain overall aesthetic appearence allow Atlanta to give added value to a room while playing a complementary role in the decoration .Atlanta , by way of its vertical convection technique and specially designed fins is made to obtain high heat output .With its valve integrated Compact Type , Atlanta is suitable for all types of installation systems . İts light weight and convection rate of 67%-70% also allow for a good distribution of heated air in the room .Atlanta like the other Models of Radiatherm is suitable to all instalation systems . İt is also suitable for bottom twin entry connection called HB connections with 50 mm betwen inlet and outlet axes . The Valve İntegrated version with thermostatic TRV head is also possible upon request .

 Model  Height (mm)  Entre-axes (mm)  Heat output per section(kcal/h)  Heat output per section (watt)  Water Content (liter)

RK 275

275

245

106

123

0,059

RK 375

375

345

137

159

0,076

RK 455

455

425

156

181

0,088

RK 475

475

445

160

186

0,094

RK 530

530

500

173

201

0,101

RK 575

575

545

184

214

0,112

RK 605

605

575

191

222

0,117

RK 755

755

725

226

263

0,143

RK 875

875

845

254

295

0,165

RK 905

905

875

261

303

0,170

RK 1005

1005

975

285

331

0,188

RK 1255

1255

1225

344

400

0,232

RK 1505

1505

1475

402

467

0,276

RK 1755

1755

1725

461

536

0,320

RK 2005

2005

1975

520

605

0,364

Color Options Wood Pattern Options
 White Ral 9010  RD - 1000
 Cream Ral 1013  RD - 1010
 Chrome Yellow Ral 1023  RD - 1020
 Orange Ral 2008  RD - 1030
 Green Ral 6019  RD - 1040

By-Pass Main Connection


Bottom opposite end connection


Up and opposite end connection


Twin connection bottom feed with integrated valve


Up and bottom same end connection


Twin connection bottom feed


The distance between the valve axes in bottom-opposite-end connection and up-opposite bottom end connection is to be taken as (45x2)=90mm in addition to radiator length. For up and down the same end connection valve center is 45 mm from the radiator. For HB connection 50 mm is between centers and 40 mm. From the start point of the radiator to the first inlet center.