Radiatherm Contact Me

Products - Class Radiator

Technical Properties

Model

Class

Section Width (mm)

40

Radiator Lenght (mm)

n x 40 ( n = number of section )

Radiator Thickness (mm)

60

Distance to the wall (mm)

115

The distance between the wall and the axis (mm)

85

Compound

1/2

Compound

Total Height - 40

  • Product Description
  • Data Heating
  • Color and Pattern Functions
  • Connection Types

Specially designed using a cross flow technic allowing Terma higher heat output and homogenous heat distribution in the room . This technic comprises “double heat transfer systems “ which occurs between the sections as a preheat area and than air flows through the louvres where the air is further heated by conduction and than returns to the room as hot air with higher speed and higher temperatures . Natural convection rate in Radiaterm-Terma is about 73%-75% of the total hot air generated by the radiator . Terma like all the other Models of Radiatherm is suitable to all installation system. Also is suitable for bottom twin entry connection called HB connections with 50 mm betwen inlet and outlet axes . The Valve İntegrated version with thermostatic TRV head is also possible upon request .

 Model  Height  Entre Axis  Thermal power per section (kcal / h)  Thermal power per section (watts)  Capacity (liter)

RC 285

285

245

42

48

0,059

RC 385

385

345

51

60

0,076

RC 465

465

425

62

72

0,088

RC 485

485

445

65

76

0,094

RC 540

540

500

75

87

0,101

RC 585

585

545

82

95

0,112

RC 615

615

575

88

102

0,117

RC 765

765

725

114

133

0,143

RC 885

885

845

136

158

0,165

RC 915

915

875

140

163

0,170

RC 1015

1015

975

158

184

0,188

RC 1265

1265

1225

202

235

0,232

RC 1515

1515

1475

247

287

0,276

RC 1765

1765

1725

291

338

0,320

RC 2015

2015

1975

335

390

0,364

Color and Pattern Functions Color and Pattern Functions
 white Ral 9010  RD - 1000
 Cream Ral 1013  RD - 1010
 Bright yellow Ral 1023  RD - 1020
 Orange Ral 2008  RD - 1030
 pale green Ral 6019  RD - 1040

By-Pass Main Connection


Bottom opposite end connection


Up and opposite end connection


Twin connection bottom feed with integrated valve


Up and bottom same end connection


Twin connection bottom feed


The distance between the valve axes in bottom-opposite-end connection and up-opposite bottom end connection is to be taken as (45x2)=90mm in addition to radiator length. For up and down the same end connection valve center is 45 mm from the radiator. For HB connection 50 mm is between centers and 40 mm. From the start point of the radiator to the first inlet center.