Radiatherm Contact Me

Products - Lara Radiator

Technical Properties

Model

Lara

Section Width (mm)

55

Radiator Lenght (mm)

n x 55 ( n = number of section )

Radiator Thickness (mm)

40

Distance to the wall (mm)

95

The distance between the wall and the axis (mm)

75

Compound

1/2

Compound

Total Height - 45

  • Product Description
  • Data Heating
  • Color and Pattern Functions
  • Connection Types

Specially designed using a cross flow technic allowing Terma higher heat output and homogenous heat distribution in the room . This technic comprises “double heat transfer systems “ which occurs between the sections as a preheat area and than air flows through the louvres where the air is further heated by conduction and than returns to the room as hot air with higher speed and higher temperatures . Natural convection rate in Radiaterm-Terma is about 73%-75% of the total hot air generated by the radiator . Terma like all the other Models of Radiatherm is suitable to all installation system. Also is suitable for bottom twin entry connection called HB connections with 50 mm betwen inlet and outlet axes . The Valve İntegrated version with thermostatic TRV head is also possible upon request .

 Model  Height  Entre Axis  Thermal power per section (kcal / h)  Thermal power per section (watts)  Capacity (liter)

RL 290

290

245

39

45

0,062

RL 390

390

345

63

73

0,080

RL 470

470

425

82

95

0,090

RL 490

490

445

86

100

0,097

RL 545

545

500

99

115

0,103

RL 590

590

545

110

128

0,115

RL 620

620

575

117

136

0,120

RL 770

770

725

152

177

0,147

RL 890

890

845

180

209

0,168

RL 920

920

875

187

217

0,173

RL 1020

1020

975

211

245

0,191

RL 1270

1270

1225

270

314

0,235

RL 1520

1520

1475

328

381

0,279

RL 1770

1770

1725

387

450

0,323

RL 2020

2020

1975

446

519

0,368

Color and Pattern Functions Color and Pattern Functions
 white Ral 9010  RD - 1000
 Cream Ral 1013  RD - 1010
 Bright yellow Ral 1023  RD - 1020
 Orange Ral 2008  RD - 1030
 pale green Ral 6019  RD - 1040

By-Pass Main Connection


Bottom opposite end connection


Up and opposite end connection


Twin connection bottom feed with integrated valve


Up and bottom same end connection


Twin connection bottom feed


The distance between the valve axes in bottom-opposite-end connection and up-opposite bottom end connection is to be taken as (45x2)=90mm in addition to radiator length. For up and down the same end connection valve center is 45 mm from the radiator. For HB connection 50 mm is between centers and 40 mm. From the start point of the radiator to the first inlet center.